Is the endoscope camera a common equipment in the imaging department? If you choose to use a medical endoscope camera, you should also check the manufacturer's qualifications you choose to order, as well as the application cases of this product, plus the connection between the endoscope camera and the monitor and the optical endoscope camera. Clearly viewing the lesion location requires skilled operation of the machine and attention to its precautions when using it.

Precautions for using the medical endoscope camera: Do not discount the light guide during use, so as not to damage the light guide and affect the transmission of light; 2-3 seconds should be interval between two times of switching the machine; Shake the instrument, and do not connect or disassemble any parts of the instrument; the instrument should be used in a clean and ventilated room, and avoid placing it with chemicals and electrical appliances with strong electromagnetic and electric fields; the surface of the instrument is easy to absorb dust due to static electricity. When wiping, please disconnect the power first, and wipe with soft absorbent cotton to avoid surface scratches; when there is dust on the surface of the camera lens, it should be wiped with absorbent cotton and alcohol;

The instrument should avoid frequent switching, otherwise it will be easily damaged. When the instrument is not in use, the power supply should be turned off, the external power supply should be unplugged, and the cover should be covered; when it is not used for a long time, it should be wiped clean, placed in the packaging box, and powered on and run regularly (usually once every other month); endoscope When the camera device fails to function, it is forbidden to open the case by yourself, and you should contact the company for maintenance; the surface temperature of the applied part of the instrument exceeds 41 ℃, suspend use, let it cool down and then continue to use it to avoid burns; replace When illuminating the LED light source, be sure to hire an experienced person to replace it; before using the endoscope camera, a suitable filter should be attached to prevent damage to the eyes when the endoscope camera light exit window transmits high-energy light;

The installation and commissioning of the equipment can only be completed by medical technicians who have received formal training and are qualified to operate. Before each use, check the endoscope camera and endoscope camera attachment parts for hazards such as rough surfaces, sharp edges or protrusions.

First, check whether the power supply is normal, whether the power cord of the host is connected, and has been inserted into the power socket; check whether the connection of each connector is normal. Secondly, for the analysis and elimination of unnecessary fault phenomena:

Fault 1: There is no image in the image display area

Reason analysis: Is the power supply of the camera connected well; is the endoscope camera a common equipment in the imaging department? Is the connection line of the camera well connected with the light source; is the camera turned on in the software;

Method of exclusion:

1. Reconnect the cable;

2. Open button;

Fault 2: The power indicator light is not on

Detect power plugs and fuses;

Trouble 3: The reflected light of the irradiated object is strong, use the image brightness minus key to adjust to reduce the light spot; if you encounter problems with machine parts, please call the manufacturer and ask experienced technicians to repair.

Attention should be paid to the use of the device: if the object to be illuminated is not clear, adjust the connection of the lens and adjust the focus to make the image clear; ensure that the power plug is not loose, and then turn on the power switch after it is plugged in; Confirm whether it is loose to prevent damage to the device by falling; please keep away from strong interference devices.

Reminder: Nowadays, with the continuous improvement of medical imaging technology, the demand for equipment is also increasing. The endoscope camera is widely used in various operations. Is the endoscope camera a commonly used equipment in the imaging department? The pictures reflected by the doctor through the instrument can be visually Under the circumstance of the operation, the success rate is greatly improved. What is the role of the medical endoscope camera? Therefore, the normal use of the machine is very important, but the machine also has a lifespan. After a long time of use and movement, there will always be various large and small sizes. small problem.